A comparative study on selectivity and sensitivity of new chromium and copper electrodes

Jan 18, 2024

Scientific Reports volume 12, Article number: 13400 (2022) Cite this article

736 Accesses

1 Citations

1 Altmetric

Metrics details

4-Methylcoumarin-7-yloxy-N-phenyl acetamide and 4-methylcoumarin-7-yloxy-N-4-nitrophenyl acetamide were synthesized and used as new ionophores in the carbon paste matrix to produce two novel potentiometric modified electrodes. The selectivity of the electrode changed from copper (II) to chromium (III) with the addition of a nitro group to the phenyl ring of the ionophore. The ionophores’ tendency to ions was confirmed by UV–visible spectrophotometry. Both electrodes were modified by multi-walled carbon nanotubes (MWCNTs) as an excellent modifier of carbon paste electrode (CPE). The best sensor response in the case of copper (II) selective CPE was obtained by 5% ionophore, 65% graphite powder, 5% MWCNT, and 25% paraffin oil. In addition, in the case of chromium (III) selective CPE, these conditions are 20% ionophore, 50% graphite powder, 5% MWCNT, and 25% paraffin oil. The copper (II) selective CPE showed a Nernstian slope of 32.15 mV/decade within the concentration range of 1.0 × 10–10–1.0 × 10–1 mol L−1, while chromium (III) selective CPE showed a Nernstian slope of 19.28 mV/decade over the concentration range of 1.0 × 10–10–7.0 × 10–3 mol L−1. The electrodes have short response time of less than 5 s and were used successfully to determine copper (II) in wastewater and to speciation of chromium (III) and chromium (VI).

Toxic metals have been discharged into the environment because of global industrialization and have caused serious concerns worldwide by affecting human health1,2. For example, copper is needed for the appropriate function of several important enzyme systems. Enzymes containing copper are cytochrome-c oxidase, ceruloplasmin, monoamine oxidase, tyrosinase, phenylalanine hydroxylase, and lysyl oxidase. On the other hand, toxicity is caused by the excess quantity of copper. For instance, Wilson disease is an autosomal recessive disorder caused by copper accumulation in the eyes, liver, and brain. Wilson disease influences the hepatic intracellular transport of copper and its consequent inclusion into bile and ceruloplasmin3. In addition, two various oxidation states of chromium normally found in natural waters are Cr (III) and Cr (VI). Both chromium types enter the environment from different sources at the effluent discharge of electroplating, tanning industries, cooling water power, oxidative dying, steelworks, and chemical industry4. Chromium has totally opposite physiological effects on the biological systems regarding its oxidation state. Chromium (III) is a key element in mammals to maintain lipid, glucose, and protein metabolism. However, Cr (VI) is a toxic material as it can oxidize other species and has adverse impacts on the lung, kidneys, and liver. Thus, it is essential to determine both species considering these two contrary impacts precisely. Several speciation studies have been conducted on different features and toxicity of the chemical forms of chromium4,5,6. Therefore, it is a critical issue to measure these ions owing to the narrow boundary between their toxicity and essentially.

Analytical methods such as atomic absorption spectroscopy (AAS)7,8,9, X-ray fluorescence (XRF)10,11, and inductively coupled plasma-atomic emission spectroscopy (ICP-AES)12,13,14 are performed to determine the trace level of metals like copper and chromium. Nevertheless, these procedures have some disadvantages based on the cost and time of routine analysis and the tedious sample preparation process. Hence, the search for new simple and rapid methods for heavy metal measurement is a challenging goal.

Electrochemical sensors are extensively used for determining different species regarding their desirable selectivity and higher sensitivity in their responses15,16,17,18,19,20,21,22,23,24,25,26,27,28. In this regard, potentiometric carbon paste electrodes (CPEs) are extensively used as simple instruments for detecting different analytes regarding their facile construction, higher signal-to-noise ratio, easy renewability of the surface, stability of response, low-cost methods, lower ohmic resistance, and not requiring the internal solution29,30. More prominently, carbon paste electrodes can be simply modified with different kinds of inorganic or organic modifiers by only mixing the modifier with binder and carbon in the paste preparing stage. The electrode's surface state can be improved by modification, which significantly increases the target signals. The potentiometric CPEs’ ion-sensing features are primarily based on the utilized sensing materials’ nature25,26,27,28,29,30,31,32. Recently, carbon-based nanomaterials have been widely exploited as electron–ion exchangers to improve electrode performance because of their higher specific surface area, good hydrophobicity, chemical stability, and electrical conductivity16,17,18,19,20,21,22,23,24,25,26,27,28,29.

In this research, we synthesized 4-methylcoumarin-7-yloxy-N-phenyl acetamide (ligand A) and 4-methylcoumarin-7-yloxy-N-4-nitrophenyl acetamide (ligand B) for the first time and used them as new ionophores to fabricate modified carbon paste electrodes for measurement of the copper (II) and chromium (III) ions potentiometrically. These two ionophores have a slight difference in structure, which is related to the existence of a nitro group in the phenolic ring of one of them. Therefore, the effect of ionophore molecular structure on selectivity was investigated, and affinity to several metals was compared. Also, both electrodes were modified by multi-walled carbon nanotubes (MWCNTs) and found that the electrodes’ response was improved using MWCNTs. To the best of our knowledge, these are the first ion selective CPEs, prepared with these ionophores as the recognition element of the electrode.

In this study, after synthesis of the ligand A and B, their interaction with some metal cations was evaluated by UV–visible spectrophotometry. The reason for this evaluation was to find the suitable cation to form the most stable complex with each ligand. Then, two new modified carbon paste electrodes were fabricated for the potentiometric measurement of copper (II) and chromium (III). Composition of the modified CPEs was optimized, and the effect of various parameters on the potential response of two modified electrodes was studied. The results of these investigations are presented below.

Achieving the high selectivity of the potentiometric sensor depends on discovering the suitable cation to form the most strong and stable complex with the sensing material. Because ligand A and B have electron-donating atoms (nitrogen and oxygen) in their structure, their complexation with transition or soft metals is predictable. The ionophore's affinity to several metals was scrutinized by UV–visible spectrophotometry before preparing the modified CPEs21,33. Therefore, equivalent quantities of different ions (Cr3+, Cu2+, Ca2+, Co2+, Mg2+, Fe2+, Zn2+, Ag+, Mn2+, Hg2+, Cd2+, Ni2+ and Pb2+) were added to each ionophore solution one by one. The UV–Vis spectra (Fig. 1) were recorded to assess the absorption alterations.

The UV–visible spectrum changes of 1.0 × 10–5 M (a) ligand A and (b) ligand B solution, after addition of 300 µL of 1 mM solutions containing one of the Cr3+, Cu2+, Ca2+, Co2+, Mg2+, Fe2+, Zn2+, Ag+, Mn2+, Hg2+, Cd2+, Ni2+ and Pb2+ cations.

The ligand A and B spectra showed the highest variation in the ionophore absorption after copper (II) and chromium (III) addition (Fig. 1a,b). This result can be attributed to the more affinity for complexing between the ligand A and copper (II), and complexing between ligand B and chromium (III) compared to the other ions. Hence, 4-methylcoumarin-7-yloxy-N-phenyl acetamide and 4-methylcoumarin-7-yloxy-N-4-nitrophenyl acetamide can serve as neutral ion carriers in producing copper (II) and chromium (III) modified CPEs, respectively.

The linear dynamic range, sensitivity, and selectivity of an ion-selective electrode are a function of its composition29. Therefore, the effect of the paste composition on the modified CPEs’ potential responses was investigated. To this end, several electrodes were fabricated with various compositions (Table 1). Unmodified CPE was made by combining 75% of graphite powder with 25% of paraffin (no. 1). Based on the obtained results, the electrode without the ionophore represented poor sensitivity to copper (II) and chromium (III) cations. Modified pastes were made similarly. However, the graphite powder was combined with a favored weight of ligand A or B, as given in Table 1. As can be seen, an increase in ligand A level in the CPEs (no. 2 and 3) from 3 to 5 mg led to an increased slope of the calibration curve for copper (II) selective electrode from 19.72 mV/decade to 25.45 mV/decade. Also, increasing the amount of the ligand B in the CPEs (no. 7–9) from 5 to 20 mg led to an increased slope of the calibration curve chromium (III) selective electrode from 12.07 mV/decade to 15.11 mV/decade. It was revealed that the quantity of the ionophore is the key factor in the suggested carbon paste electrodes with the main role in the potential response of the sensors. Improving the response of electrodes by increasing the ionophores amounts shows the affinity of the ligand A and B to copper (II) and chromium (III) ions, respectively29. But, more increase in the ligand A (no. 4 and 5) lowered the calibration curve slope for copper (II) selective electrode, which can be due to heterogeneity in the carbon paste.

The MWCNTs can be used as a superior candidate for the conventional modifier to modify CPE and, thus, improve the electrodes’ electrochemical performance. The main reason for using this structure is its greater electrical conducting capability and higher specific surface area30. Hence, we also assessed the effects of inserting some MWCNTs in the electrode composition on the CPEs’ potentiometric response. According to Table 1, both electrodes show the Nernstian slope when MWCNTs were used in the carbon paste composition (no. 6 and 10). Also, the addition of MWCNTs in the electrode composition improves the detection range of the electrode from 1 × 10–8–1 × 10–1 mol L−1 to 1 × 10–10–1 × 10–1 mol L−1 for copper (II) electrode (no. 3 and 6) and from 1 × 10–8–1 × 10–3 mol L−1 to 1 × 10–10–7 × 10–3 mol L−1 for chromium (III) electrode (no. 9 and 10).

Accordingly, a composition of 5% of ligand A, 65% graphite powder, 5% MWCNT, and 25% paraffin oil was found to have the best performance and was chosen as the optimal composition for copper (II) electrode. Furthermore, a composition of 20% ligand B, 50% graphite powder, 5% MWCNT, and 25% paraffin oil showed the best performance and was chosen as the optimal composition for chromium (III) electrode.

The test solution's pH is one of the most important factors in most ISEs’ performance. The effect of the solution's pH on the response of the proposed modified electrodes was assessed on 1.0 × 10–4 mol L−1 analyte ions with various pH values. Copper (II) and chromium (III) solutions were prepared with different pH in the range of 2 to 10 by adding dilute solutions of NaOH or HNO3. Figure 2 shows the potential variation as a function of pH. During all experiments, the electrode's composition was maintained constant. According to the results, the potential is constant in the pH range of 4.5 to 8.5 (Fig. 2a) and 5–7 (Fig. 2b) for modified copper (II) and chromium (III) selective electrodes, respectively. These results suggest the good performance of the sensors in this pH range. The fluctuations below pH of 4.5 and 5 could be associated with the partial protonation of the utilized ionophore. Protons can compete with copper (II) and chromium (III) at higher H+ concentrations. Based on the observations, at pH values below 4.5 and 5, the concentration of H+ is higher enough to win in the competition with copper (II) and chromium (III), respectively. At higher pH values, the changes could be caused by the formation of various copper (II) and chromium (III) hydroxides26,28.

The effects of pH on the potential response of the (a) copper (II) selective CPE and (b) chromium (III) selective CPE.

Response time is the time required for the potential response to obtain values within ± 1 mV of the ultimate equilibrium potential18. It is a key parameter to detect the application of the suggested technique in routine works. The average response time was about 3–4 s in low to high concentrations in the case of the copper (II) selective CPE (Fig. 3a), and in the case of the chromium (III) selective CPE, it was about 3–5 s (Fig. 3b). The quick exchange kinetics of complexation-decomplexation of copper (II) and chromium (III) ions with the ionophores at the boundary of carbon paste-solution can be the reason for these short response times.

Response time of (a) copper (II) selective CPE and (b) chromium (III) selective CPE in various concentrations of ions.

The response of an ion-selective electrode to the target ion is one of its key features over other ions and species existing in the solution. This feature is termed the potentiometric-selectivity coefficient.

The selectivity coefficients of the two suggested electrodes were assessed by the well-known Matched Potential Method (MPM)34,35. In MPM, first, the changes in the potentials by altering the primary ion activity are determined. The interfering ion is then added to an equal reference solution until achieving the same potential changes. The selectivity coefficient KMPM is obtained as:

where ΔaA = a′A–aA, aA represents the initial primary ion activity and a′A the activity of A, while existing the interfering ion (i.e., aB). A KMPM value of 1.0 represents the sensor with similar responses to both interfering and primary ions, with the smaller values denoting its higher selectivity. The results obtained are summarized in Table 2 and Fig. 4. All selectivity coefficients are much less than 1.0, indicating the higher selectivity of the developed electrodes for the analytes.

The values of KMPM of proposed CPEs for a variety of different cations; red bars represent KMPM of copper (II) selective electrode, and blue bars represent KMPM chromium (III) selective electrode.

In this step, measuring ranges, detection limits (DL), and repeatability of the modified CPEs were evaluated.

The potential response of electrodes showed a linear concentration (activity) range of 1 × 10–1 to 1 × 10–10 mol/L and 7 × 10–3 to 1 × 10–10 mol/L of copper (II) and chromium (III) ion in the calibration solution with Nernstian slopes of 32.15 and 19.28 mV/decade (Fig. 5) for copper (II) and chromium (III) selective CPEs, respectively. The Nernstian slope is a very interesting factor in discovering whether ion-selective electrodes are conveniently employed in analytical applications. This value is estimated using the slope curve of the potential measured in (EMF/mV) against the log activity of the standard solution (M) (Fig. 5). The optimal value of 59.10/n (mV/decade) was obtained for the Nernstian slope, where (n) is the valency9. Since the Nernstian slopes in this research were 32.15 and 19.28 mV/decade for copper (II) and chromium (III) selective CPEs, respectively, the proposed electrodes are acceptable to use in the analytical applications of copper (II) and chromium (III).

Calibrations curves of (a) copper (II) and (b) chromium (III) selective CPEs.

The detection limits were calculated by substituting the potential value that is the projection of the cut-off point in the correct equation. The electrodes display a low detection limit of 9.0 × 10–11 mol/L and 1.0 × 10–10 mol/L for copper (II) and chromium (III), respectively.

The repeatability of the electrodes was assessed with 4 repetitive measurements of analyte solution (1.0 × 10–6 mol L−1) under the optimized circumstances with modified CPEs. The precision of ion measurement by copper (II) and chromium (III) selective CPEs (based on the relative standard deviation) were determined to be 4.8% and 4.3%, respectively.

The long terms stability and lifetime of the proposed CPEs were assessed by recalibration in standard solutions periodically and calculation of the optimized electrode's slope within some weeks in the linear concentration range of each of the electrodes (Fig. 6). During this period, the CPEs were used weekly. The suggested electrodes were washed gently with distilled water, dried, and kept at room temperature.

The lifetime of the (a) copper (II) and (b) chromium (III) selective CPEs.

The obtained results revealed that the copper (II) selective CPE could be used for 21 weeks with no considerable changes in its slope. In the case of chromium (III) selective CPE, the lifetime was about 13 weeks. By the end of this time, there was a slight gradual reduction in the slopes, indicating that the lifetime of the presented copper (II) and chromium (III) selective CPEs were more than 5 and 3 months, respectively.

Based on the general principle of the working mechanism of the potentiometric ion-selective electrodes, during a potentiometric test, the ion recognition element (known as ionophore) located at the electrode surface interacts with the target ion and up-takes it to the electrode surface. Thus, the considered ionic species’ electrochemical potential on the electrode surface is increased compared with the solution layer adjacent to the electrode. Hence, an electrical potential is created across the electrode/solution interface.

Herein, the ligand A and ligand B play the role of ionophore for the CPEs. Due to the existence of oxygen and nitrogen electron-donating atoms in the structure of these ionophores, charge/dipole interactions and their complexation with transition and soft metals are predictable.

In the 1960s, Ralph Pearson classified Lewis bases and Lewis acids as soft and hard. The acids and bases suitable for interaction can be predicted using Pearson's hard and soft (Lewis) acid–base (HSAB). It is noteworthy that metal ions are electron-pair acceptors and thus are Lewis acids, while ligands are electron-pair donors and thus are Lewis bases. Therefore, the Lewis acid–base theory can be used to describe metal–ligand interactions. As copper (II) ions are a soft acid in Pearson classification, they are expected to have stronger interactions with the relatively soft nitrogen atoms of ligand A as a Lewis base36.

But, in the case of the ligand B, adding a nitro group to the phenyl ring affected the ionophore selectivity. Here, the selectivity has changed from copper (II) to chromium (III). It seems that due to the resonant and electron-withdrawing effect of the nitro group, the hardness of the amide's nitrogen atom increases and its affinity to harder ions such as chromium (III) increases. In other words, its tendency to share its electrons in a covalent bond has decreased and, therefore, it needs a more electronegative and stronger acid such as chromium (III) to form a complex. Table 3 compares the absolute electronegativity and hardness of the copper (II) and chromium (III) ions.

The applicability of the suggested CPEs was evaluated by using them as indicator electrodes in the titration of 25 mL 1.0 × 10–4 mol/L copper (II) and chromium (III) solution with 1.0 × 10–2 mol/L EDTA.

The resultant curves (Fig. 7) indicate that increasing the amount of EDTA leads to a reduction in the potential values because of creating complexation between analyte ions with EDTA and decreasing the concentration of free analyte ions in solution. The sharp endpoint in titration curves causes the accurate estimation of copper (II) and chromium (III) concentration throughout the experiment.

The potential titration curves of 25 mL 1.0 × 10–4 mol/L analyte solution with 1.0 × 10–2 mol/L of EDTA by using (a) copper (II) and (b) chromium (III) selective CPEs.

For examining the applicability of the two proposed electrodes to real specimens, the enhanced electrodes were used to determine copper (II) and chromium (III) amounts in industrial manufactory wastewater samples. The samples were diluted 10 times and the pH values of the solutions were set. The analysis was performed by the proposed CPEs and flame atomic absorption spectroscopy (FAAS) methods. The results of the measurements are shown in Table 4. As can be observed, the results were comparable with those obtained by FAAS. Thus, both modified CPEs can be a good alternative to determine successfully copper (II) and chromium (III) in real samples.

Also, the chromium (III) selective CPE was used to specify hexavalent and trivalent chromium in standard samples. As shown in Table 5, the results obtained by the suggested CPE and the real amount of the hexavalent and trivalent chromium are in satisfactory agreement.

Table 6 compares some important features of the presented CPEs with the equivalent values for some formerly reported copper (II) and chromium (III) selective electrodes in terms of different ionophores37,38,39,40,41,42,43,44,45,46,47,48.

According to the table, in most cases, the suggested electrodes represent superior performance to the formerly reported electrodes. Overall, the results show an improvement in the working range, detection limit, response time, usable pH range, and the lifetime of copper (II) selective CPE. Regarding chromium (III) selective CPE, an improvement in the working range, detection limit, and response time can be seen, and the electrode lifetime is similar to the best-reported chromium (III) selective CPEs.

Ionophores were synthesized using aniline, 4-nitroaniline, resorcinol, ethyl acetoacetate, sulfuric acid, ethyl bromoacetate, potassium carbonate, acetone, hydrazine hydrate, ethanol, tetrahydrofuran (THF), and copper chloride purchased from Sigma-Aldrich. Graphite powder with particle size < 20 μm from Fluka and high-purity paraffin oil and multi-walled carbon nanotubes from Sigma-Aldrich were used to prepare carbon pastes. Potassium dichromate, sodium thiosulfate, and nitrate salts of the used cations (from Merck and Sigma-Aldrich) were of the highest available purity. Double distilled deionized water was used during the experiment.

Fourier transform infrared spectra were recorded on a Bruker Tensor 27 instrument using the KBr disks. 1H and 13C nuclear magnetic resonance (NMR) spectra were recorded with an Ultra shield Bruker 400 instrument using CDCl3 as the deuterated solvent. A Bransetead Electro-Thermal B1 tool was used to determine the melting point. UV–vis spectrophotometer (Varian Cary100-Bio) was utilized to achieve absorbance curves and absorbance spectra.

The constructed ion-selective CPE, as the working electrode, was placed in a glass cell along with a double junction Ag/AgCl as the reference electrode for potentiometric measurement. The two electrodes were linked to a digital milli-voltmeter (HIOKI 3256.50) with ± 0.1 mV precision. The pH controlling was performed using a Metrohm pH-meter with a combined glass electrode.

First, 4-methyl-7-hydroxy coumarin, 4-methylcoumarin-7-yloxy ethyl acetate, and 4-methylcoumarin-7-yl-oxy acetohydrazide were synthesized as described in previous reports49,50. Then, for the synthesis of the ligand A (Fig. 8a) and ligand B (Fig. 8b), two 100 mL round-bottomed flasks were used as reaction vessels and equipped with a magnet bar and magnetic stirrer. About 10 mL of tetrahydrofuran was used as the solvent. Next, 0.1 g of 4-methylcoumarin-7-yl-oxy acetohydrazide, 0.34 g of copper (II) chloride, and 0.21 g of aniline or 4-Nitroaniline were added to the reaction vessels (Fig. 8). The reaction mixture was stirred at room temperature for 24 h.

Synthesis of (a) 4-methylcoumarin-7-yloxy-N-phenyl acetamide and (b) 4-methylcoumarin-7-yloxy-N-4-nitrophenyl acetamide.

The advancement of the reactions was monitored using thin-layer chromatography (TLC) on silica-gel as the stationary phase, and CHCl3-MeOH (2:1) was used as the mobile phase. After completing the reactions, the products were separated from the reaction mixture by liquid extraction and recrystallized using appropriate solvents. The melting point of ligand A and B were determined to be 228℃ and 274℃, respectively.

Also, the structures were characterized by H-NMR, FT IR, 1 and 13C-NMR spectroscopy techniques as follows:

Ligand A (4-methylcoumarin-7-yloxy-N-phenyl acetamide): IR (KBr, cm−1) 3364; 3075; 3040; 2915; 1703; 1660; 1625.5; 1539; 1500; 1444; 1363; 1297; 1079; 1151; 1209; 887; 850; 801; 752; 696. 1HNMR: (DMSO-d6) δ, ppm, 2.38(3H, s); 4.8(2H, s); 6.21(1H, s); 7–7.72(8H, m); 10.14(1H, s).

Ligand B (4-methylcoumarin-7-yloxy-N-4-nitrophenyl acetamide): IR (KBr, cm−1) 3303.4; 3000–3100; 291; 1689.3; 1617.4; 1566.5; 1501.3; 1395.1; 1346.6; 1332.3; 1287.4; 1261.6; 1195.8; 1164.4; 1140.2; 1111.7; 1088.5; 850.4; 831.4; 680. 1HNMR: (DMSO-d6) δ, ppm, 2.26(3H, s); 4.93(2H, s); 6.23(1H, s); 7.03(1H, s)-7.06(1H, s); 7.7(1H, d) 7.9(2H, d); 8.2(2H, d); 10.77(1H, s).

The ligand A and 4B were utilized as ionophores in the preparation of the copper and chromium selective carbon paste electrodes, respectively.

UV–visible spectrophotometry was used to assess the interaction of ionophores with some metal cations as follows. About 300 µL of aliquots of various cations solutions (1 mM) were added to a solution of ligand A and B at a concentration of 1.0 × 10–5 mol/L in acetonitrile and tetrahydrofuran. Next, the alterations in the ligand's spectrum were measured.

For fabricating the modified CPEs, the pastes were prepared by hand-mixing different amounts of the synthesized ionophore powder and various amounts of graphite, MWCNTs, and paraffin oil for 20 min. When each mixture was homogenized, a portion of the prepared paste was carefully packed into the tube tip to prevent possible air gaps. It regularly improves the electrode resistance. Electrical contact was established by inserting a copper wire into the CPE opposite end. Before usage, a piece of soft paper was used to smooth the carbon paste's external surface. The old surface was scraped out, and the new carbon paste was replaced to make a new surface. The electrode was ultimately conditioned for 24 h by soaking in a 1.0 × 10–3 mol L−1 of analyte solution. The sensor's response was validated by measuring the electromotive force (EMF) of the following electrochemical cell:

For potential measurement at 25 ± 0.1 ℃, the explained reference electrode and the carbon paste electrode were linked to a digital milli-voltmeter. The plot of EMF was made as a function of log [analyte].

To determine the concentration of Cr (VI), it must be converted to Cr (III). Therefore, before determining the Cr (VI), adding 0.1 mL of sodium thiosulfate (0.1 mol L-1) to the solution is essential. First, Cr (III) was defined, followed by adding sodium thiosulfate to the solution and reducing Cr (VI) to Cr (III). Next, it was determined as total chromium; the difference denotes the presence of Cr (VI) in the sample4.

Two new modified carbon paste electrodes were fabricated for the selective and sensitive detection of copper (II) and chromium (III) using two similar derivatives of the 4-methylcoumarin. To this end, 4-methylcoumarin-7-yloxy-N-phenyl acetamide (ligand A) and 4-methylcoumarin-7-yloxy-N-4-nitrophenyl acetamide (ligand B) were synthesized and used as a new neutral carrier to design CPEs. It was found that copper (II) and chromium (III) recognition of these modified CPEs were highly affected by the nature and structure of the ionophores. Also, ligand A showed good copper (II) ions selectively, while ligand B tended to chromium (III). Due to the resonant and electron-withdrawing effect of the nitro group in ligand B, the hardness of the amide's nitrogen atom increases compared to the ligand A. Therefore, its affinity to harder ions such as chromium (III) increases. The tendency of ionophores to copper (II) and chromium (III) ions was confirmed by UV–visible spectrophotometry. According to the obtained results, two novel potentiometric modified carbon paste electrodes were fabricated in the case of the copper electrode by 5% ionophore, 65% graphite powder, 5% MWCNT, and 25% paraffin oil. In the case of chromium electrode, these conditions were 20% ionophore, 50% graphite powder, 5% MWCNT, and 25% paraffin oil. Also, the results showed that the MWCNTs could be used as a superior candidate to modify CPE due to the excellent electrical conductivity and large specific surface area. The copper (II) selective CPE showed a Nernstian slope of 32.15 mV/decade over the concentration range of 1.0 × 10–10–1.0 × 10–1 mol L−1, while chromium (III) selective CPE showed a Nernstian slope of 19.28 mV/decade over the concentration range of 1.0 × 10–10–7.0 × 10–3 mol L−1. The electrodes indicate a stable and short response time of about 3–5 s. The proposed modified CPEs were used successfully to determine copper (II) in wastewater samples and for the determination and speciation of chromium (III) and chromium (VI). The modified CPEs demonstrated the benefits of low cost, simple design, excellent selectivity to analytes, wide concentration range, renewability, and applicability as an indicator electrode.

The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request.

Ozdemir, S., Kilinc, E. & Oner, E. T. Preconcentrations and determinations of copper, nickel and lead in baby food samples employing Coprinus silvaticus immobilized multi-walled carbon nanotube as solid phase sorbent. Food Chem. 276, 174–179. https://doi.org/10.1016/j.foodchem.2018.07.123 (2019).

Article CAS PubMed Google Scholar

Song, Y. et al. Highly efficient adsorption of Pb(II) from aqueous solution using amino-functionalized SBA-15/calcium alginate microspheres as adsorbent. Int. J. Biol. Macromol. 125, 808–819. https://doi.org/10.1016/j.ijbiomac.2018.12.112 (2019).

Article CAS PubMed Google Scholar

Hajiaghababaei, L., Amini, Z. & Shahvelayati, A. S. Removal of Pb2+, Cu2+ and Ag+ cations from wastewater by modified ZnO nanoparticles with S,N-substituted thiouracil derivative. J. Elem. 23, 1179–1196. https://doi.org/10.5601/jelem.2018.23.1.1578 (2018).

Article Google Scholar

Ganjali, M. R. et al. A novel method for fast enrichment and monitoring of hexavalent and trivalent chromium at the ppt level with modified silica MCM-41 and its determivation by inductively coupled plasma optical emission spectrometry. Quim. Nova. 29, 440–443. https://doi.org/10.1590/S0100-40422006000300007 (2006).

Article CAS Google Scholar

Nusko, R. & Heumann, K. G. Cr(III)/Cr(VI) speciation in aerosol particles by extractive separation and thermal ionization isotope dilution mass spectrometry. Fresenius. J. Anal. Chem. 357, 1050–1055. https://doi.org/10.1007/s002160050303 (1996).

Article Google Scholar

Shemirani, F., Abkenar, S. D., Mirroshandel, A. A., Niasari, M. S. & Kozania, R. R. Preconcentration and speciation of chromium in water samples by stomic absorption spectrometry after cloud-point extraction. J. Anal. Sci. 19, 1453–1456. https://doi.org/10.2116/analsci.19.1453 (2003).

Article CAS Google Scholar

Bagherian, G., Chamjangali, M., Evari, H. & Ashrafi, M. Determination of copper(II) by flame atomic absorption spectrometry after its perconcentration by a highly selective and environmentally friendly dispersive liquid–liquid microextraction technique. J. Anal. Sci. Technol. 10, 1–11. https://doi.org/10.1186/s40543-019-0164-6 (2019).

Article Google Scholar

Elyas Sodan, N., Elci, S. G., Arslan Kartal, A., Hol, A. & Elci, L. Speciation and preconcentration of chromium in real samples by magnetic polythiophene nanoparticle solid-phase extraction (SPE) coupled with microsampling injection–flame atomic absorption spectrometry (FAAS). Instrum. Sci. Technol. 49, 585–603. https://doi.org/10.1080/10739149.2021.1913746 (2021).

Article CAS Google Scholar

Shishov, A., Terno, P. & Bulatov, A. Deep eutectic solvent decomposition-based microextraction for chromium determination in aqueous environments by atomic absorption spectrometry with electrothermal atomization. Analyst 146, 5081–5088. https://doi.org/10.1039/D1AN00924A (2021).

Article ADS CAS PubMed Google Scholar

Shi, J., Jiang, Y., Zhang, B. & Zhou, J. Determination of Mn, Fe, Ni in copper alloy by X-ray fluorescence analysis. OALib. 08, 1–5. https://doi.org/10.4236/oalib.1107844 (2021).

Article CAS Google Scholar

Rajib, A., Tariqur Rahman, M. & Md. Ismail, A. B. Using X-ray fluorescence technique propagation of chromium (Cr) from poultry feeds to different parts of chicken including her eggs. J. Phys. Conf. Ser. 1718, 012015. https://doi.org/10.1088/1742-6596/1718/1/012015 (2021).

Article CAS Google Scholar

Chernikova I.I., F. S. S., Ermolaeva T.N. Analysis of copper alloys by inductively coupled plasma atomic emission spectrometry with spark sampling. Ind. Lab. Diagn. Mater. 86, 11–1. https://doi.org/10.26896/1028-6861-2020-86-3-11-19 (2020).

Tsanaktsidou, E. & Zachariadis, G. Titanium and chromium determination in feedstuffs using ICP-AES technique. J. Sep. 7, 1–9. https://doi.org/10.3390/separations7010001 (2020).

Article CAS Google Scholar

Manousi, N. & Zachariadis, G. A. Development and application of an ICP-AES method for the determination of nutrient and toxic elements in savory snack products after autoclave dissolution. J. Sep. 7, 66–75. https://doi.org/10.3390/separations7040066 (2020).

Article CAS Google Scholar

Hajiaghababaei, L., Shahvelayati, A. S. & Aghili, S. A. Rapid determination of cadmium: A potentiometric membrane sensor based on ninhydrin-pyrogallol monoadduct as a new ionophore. Anal. Bioanal. Electrochem. 7, 91–104 (2015).

CAS Google Scholar

Zhang, L., Wei, Z., Liu, P., Wei, H. & Ma, D. Performance comparison of solid lead ion electrodes with different carbon-based nanomaterials as electron-ion exchangers. J. Sens. 21, 1663. https://doi.org/10.3390/s21051663 (2021).

Article ADS CAS Google Scholar

Panahi Sarmad, A., Hajiaghababaei, L., Shahvelayati, A. S. & Najafpour, J. Development of copper-selective potentiometric sensor using a new ion carrier: A theoretical and experimental study. Russ. J. Electrochem. 57, 774–783. https://doi.org/10.1134/S1023193520120216 (2021).

Article CAS Google Scholar

Hajiaghababaei, L., Sharafi, A., Suzangarzadeh, S. & Faridbod, F. Mercury recognition: A potentiometric membrane sensor based on 4-(benzylidene amino)-3,4-dihydro-6- methyl-3-thioxo-1,2,4-triazin-5(2H)one. Anal. Bioanal. Electrochem. 5, 481–493 (2013).

Google Scholar

Faridbod, F. Pramipexole symmetric and asymmetric potentiometric PVC membrane sensors. Int. J. Electrochem. Sci. 11, 7990–8001. https://doi.org/10.20964/2016.09.64 (2016).

Article CAS Google Scholar

Hassan, S. S. M., Kamel, A. H., Amr, A. E. G. E., Fathy, M. A. & Al Omar, M. A. Paper strip and ceramic potentiometric platforms modified with nano-sized polyaniline (PANi) for static and hydrodynamic monitoring of chromium in industrial samples. Molecules 25, 629–644. https://doi.org/10.3390/molecules25030629 (2020).

Article CAS PubMed Central Google Scholar

Rashvand, H. R., Hajiaghababaei, L., Darvich, M. R., Jalali Sarvestani, M. R. & Jaberi Miyandoab, F. A liquid membrane mercury selective electrode based on 2-(NPipyridino methyl)-1-cyano cyclohexanol as a novel neutral carrier. J. Anal. Chem. 75, 1340–1347. https://doi.org/10.1134/S106193482010010X (2020).

Article Google Scholar

Jafari, M., Hajiaghababaei, L. & Darvish, M. R. Oxime-2-(1-cyclohexenyl) cyclohexanone: synthesis and application as a new ion carrier for preparation of cobalt selective potentiometric electrode. Anal. Bioanal. Electrochem. 11, 943–955 (2019).

CAS Google Scholar

Heydari, Z., Hajiaghababaei, L. & Darvish, M. R. Rapid measuring of Cu2+ ions by selective potentiometric sensor based on a newiIon carrier. Anal. Bioanal. Electrochem. 11, 278–291 (2019).

CAS Google Scholar

Khalil, S. Chitosan based nano-membrane for chromium(III) determination in pharmaceutical and foodstuff samples. Int. J. Electrochem. Sci. 16, 21116. https://doi.org/10.20964/2021.11.14 (2021).

Article CAS Google Scholar

Ali, T. A. & Mohamed, G. G. Development of chromium(III) selective potentiometric sensors for its determination in petroleum water samples using synthesized nano Schiff base complex as an ionophore. J. AOAC Int. https://doi.org/10.1093/jaoacint/qsab166 (2021).

Article PubMed Google Scholar

Frag, E. Y., Mohamed, N. M. & Elashery, S. E. A. Exploitation of o-benzoyl benzoic acid as an efficient electroactive material for selective determination of Cr (III) ions in pharmaceutical samples and industrial waste water using carbon sensor. Anal. Chim. Acta. 1154, 338322–338332. https://doi.org/10.1016/j.aca.2021.338322 (2021).

Article CAS PubMed Google Scholar

Frag, E. Y., Mohamed, M. E. B. & Fahim, E. M. Application of carbon sensors for potentiometric determination of copper(II) in water and biological fluids of Wilson disease patients. Studying the surface reaction using SEM, EDX, IR and DFT. Biosens. Bioelectron. 118, 122–128. https://doi.org/10.1016/j.bios.2018.07.024 (2018).

Article CAS PubMed Google Scholar

Mashhadizadeh, M. H., Khani, H., Foroumadi, A. & Sagharichi, P. Comparative studies of mercapto thiadiazoles self-assembled on gold nanoparticle as ionophores for Cu(II) carbon paste sensors. Anal. Chim. Acta. 665, 208–214. https://doi.org/10.1016/j.aca.2010.03.023 (2010).

Article CAS PubMed Google Scholar

Afkhami, A., Shirzadmehr, A., Madrakian, T. & Bagheri, H. New nano-composite potentiometric sensor composed of graphene nanosheets/thionine/molecular wire for nanomolar detection of silver ion in various real samples. Talanta 131, 548–555. https://doi.org/10.1016/j.talanta.2014.08.004 (2015).

Article CAS PubMed Google Scholar

Alizadeh, T., Sabzi, R. & Alizadeh, H. Synthesis of nano-sized cyanide ion-imprinted polymer via non covalent approach and its use for the fabrication of a CN selective carbon nanotube impregnated carbon paste electrode. Talanta https://doi.org/10.1016/j.talanta.2015.09.043 (2016).

Article PubMed Google Scholar

Alizadeh, T. & Jamshidi, F. Synthesis of nanosized sulfate-modified α-Fe2O3 and its use for the fabrication of all-solid-state carbon paste pH sensor. J. Solid State Electrochem. 19, 1053–1062. https://doi.org/10.1007/s10008-014-2716-4 (2015).

Article CAS Google Scholar

Abbastabar-Ahangar, H. et al. Ion-selective carbon paste electrode based on new tripodal ligand for determination of cadmium (II). J. Incl. Phenom. Macrocycl. Chem. 63, 287–293. https://doi.org/10.1007/s10847-008-9519-0 (2009).

Article CAS Google Scholar

Jalali sarvestani, M. R., Hajiaghababaei, L., Najafpour, J. & Suzangarzadeh, S. 1-(6-choloroquinoxaline-2-yl) hydrazine as an excellent ionophore for preparation of a cobalt selective electrode and potentiometric measuring of vitamin B12 in pharmaceutical samples. Anal. Bioanal. Electrochem. 10, 675–698 (2018).

Google Scholar

Umezawa, Y., Umezawa, K. & Sato, H. Selectivity coefficients for ion-selective electrodes: Recommended methods for reporting K A, B pot values (Technical Report). Pure Appl. Chem. 67, 507–518. https://doi.org/10.1351/pac199567030507 (1995).

Article Google Scholar

Umezawa, Y. et al. Potentiometric selectivity coefficients of ion-selective electrodes. Part II. Inorganic anions (IUPAC Technical Report). Pure Appl. Chem. 74, 923–994. https://doi.org/10.1351/pac200274060923 (2002).

Article CAS Google Scholar

Pearson, R. G. Absolute electronegativity and hardness: Application to inorganic chemistry. Inorg. Chem. 27, 734–740. https://doi.org/10.1021/ic00277a030 (1988).

Article CAS Google Scholar

Abbaspour, A. & Moosavi, S. M. M. Chemically modified carbon paste electrode for determination of copper(II) by potentiometric method. Talanta 56, 91–96. https://doi.org/10.1016/S0039-9140(01)00549-5 (2002).

Article CAS PubMed Google Scholar

Bagheri, H., Shirzadmehr, A. & Rezaei, M. Determination of copper ions in foodstuff products with a newly modified potentiometric carbon paste electrode based on a novel nano-sensing layer. Ionics 22, 1241–1252. https://doi.org/10.1007/s11581-016-1646-9 (2016).

Article CAS Google Scholar

Mazloum Ardakani, M., Mandegari, A. A., Masoum, S. & Naeimi, H. Multiwall carbon nanotubes modified carbon paste electrode for determination of copper(II) by potentiometric and impedimetric methods. J. Nanostruct. 2, 333–343. https://doi.org/10.7508/jns.2012.03.008 (2012).

Article Google Scholar

Mashhadizadeh, M. H., Ramezani, S. & Ebrahimi, S. Potentiometric determination of nanomolar concentration of Cu (II) using a carbon paste electrode modified by a self-assembled mercapto compound on gold nanoparticles. Sens. Actuators B Chem. 169, 305–311. https://doi.org/10.1016/j.snb.2012.04.086 (2012).

Article CAS Google Scholar

Rajabi, H. R., Zarezadeh, A. & Karimipour, G. Porphyrin based nano-sized imprinted polymer as an efficient modifier for the design of a potentiometric copper carbon paste electrode. RSC Adv. 7, 14923–14931. https://doi.org/10.1039/c6ra27288f (2017).

Article ADS CAS Google Scholar

Soleimani, M. & Afshar, M. Potentiometric sensor for trace level analysis of copper based on carbon paste electrode modified with multi-walled carbon nanotubes. Int. J. Electrochem. Sci. 8, 8719–8729 (2013).

CAS Google Scholar

Issa, Y. M., Ibrahim, H. & Shehab, O. R. New copper(II)-selective chemically modified carbon paste electrode based on etioporphyrin I dihydrobromide. J. Electroanal. Chem. 666, 11–18. https://doi.org/10.1016/j.jelechem.2011.11.024 (2012).

Article CAS Google Scholar

Zhou, W., Chai, Y., Yuan, R., Guo, J. & Wu, X. Organically nanoporous silica gel based on carbon paste electrode for potentiometric detection of trace Cr(III). Anal. Chim. Acta. 647, 210–214. https://doi.org/10.1016/j.aca.2009.06.007 (2009).

Article CAS PubMed Google Scholar

Sharif Manesh, S., Masrournia, M. & Beyram Abady, A. Determination of chromium(III) and magnesium(II) ions in pharmacological and real water samples using potentiometric sensors based on chitosan schiff base derivative as green and sensitive ionophore. Anal. Bioanal. Electrochem. 12, 180–192 (2020).

Google Scholar

Heidari, Z. & Masrounia, M. A novel modified carbon paste electrode for the determination of chromium(III) in water. J. Anal. Chem. 73, 824–831. https://doi.org/10.1134/s1061934818080105 (2018).

Article CAS Google Scholar

Zayed, M. A., Abbas, A. A., Mahmoud, W. H., Ali, A. E. & Mohamed, G. G. Development and surface characterization of a bis(aminotriazoles) derivative based renewable carbon paste electrode for selective potentiometric determination of Cr(III) ion in real water samples. Microchem. J. 159, 105478–105485. https://doi.org/10.1016/j.microc.2020.105478 (2020).

Article CAS Google Scholar

Shojaei, E., Masrournia, M., Beyramabadi, A. & Behmadi, H. Design and fabrication of carbon paste electrode for determination of Cr(III) ion in real water samples using a new synthesis Schiff base as selective ionophore. Eurasian Chem. Commun. 2, 750–759. https://doi.org/10.33945/sami/ecc.2020.7 (2020).

Article CAS Google Scholar

Guan, A. Y. et al. Synthesis and bioactivity of novel coumarin derivatives. Nat. Prod. Commun. 6, 1917–1920. https://doi.org/10.1177/1934578X1100601232 (2011).

Article CAS PubMed Google Scholar

Hamdi, N., Al-Ayed, A. S., Ben Said, R. & Fabienne, A. Synthesis and characterization of new thiazolidinones containing coumarin moieties and their antibacterial and antioxidant activities. Molecules 17, 9321–9334. https://doi.org/10.3390/molecules17089321 (2012).

Article CAS PubMed PubMed Central Google Scholar

Download references

The author thanks the Research Council of the Islamic Azad University of Yadegar-e-Imam Khomeini (RAH) Shahre Rey branch for supporting this work.

Department of Chemistry, Yadegar-e-Imam Khomeini (RAH) Shahre Rey Branch, Islamic Azad University, Tehran, Iran

Elnaz Bakhshi Sarabi, Leila Hajiaghababaei, Mohammad Reza Allahgholi Ghasri, Seyed Enayatollah Mottaghinejad & Ali Parsa

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

L.H. and M.R.A.G. are supervisors and wrote the main manuscript. S.E.M. wrote the section of the synthesis of ionophores in manuscript. E.B.S. is Ph.D. student and has prepared the figures with the help of A.P. All authors reviewed the manuscript.

Correspondence to Leila Hajiaghababaei or Mohammad Reza Allahgholi Ghasri.

The authors declare no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and Permissions

Bakhshi Sarabi, E., Hajiaghababaei, L., Allahgholi Ghasri, M.R. et al. A comparative study on selectivity and sensitivity of new chromium and copper electrodes. Sci Rep 12, 13400 (2022). https://doi.org/10.1038/s41598-022-17662-6

Download citation

Received: 10 June 2022

Accepted: 28 July 2022

Published: 04 August 2022

DOI: https://doi.org/10.1038/s41598-022-17662-6

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.